Norma

EN12209

Dig. 1

CATEGORY OS USE

Class 1

for use by people with a high incentive to exercise care and with a small chance of misuse, e.g. residential doors

Class 2

for use by people with some incentive to exercise care but where there is some chance of misuse, e.g. office doors

Class 3

for use by the public where there is little incentive to exercise care and where there is a high chance of misuse, e.g. doors in public buildings

DIG. 2

DURABILITY

A

50.000 test cycles, no load on latch bolt

B

100.000 test cycles, no load on latch bolt

C

200.000 test cycles, no load on latch bolt

F

50.000 test cycles, 10 N load on latch bolt

G

100.000 test cycles, 10 N load on latch bolt

H

200.000 test cycles, 10 N load on latch bolt

L

100.000 test cycles, 25 N load on latch bolt

M

200.000 test cycles, 25 N load on latch bolt

R

100.000 test cycles, 50 N load on latch bolt

S

200.000 test cycles, 50 N load on latch bolt

W

100.000 test cycles, 120 N load on latch bolt

X

200.000 test cycles, 120 N load on latch bolt

DIG. 3

DOOR MASS AND CLOSING FORCE

1

up to 100kg door measure, 50 N maximum closing force

2

up to 200kg door measure, 50 N maximum closing force

3

above 200kg door measure, 50 N maximum closing force

4

up to 100kg door measure, 25 N maximum closing force

5

up to 200kg door measure, 25 N maximum closing force

6

above 200kg door measure, 25 N maximum closing force

7

up to 100kg door measure, 15 N maximum closing force

8

up to 200kg door measure, 15 N maximum closing force

9

above 200kg door measure, 15 N maximum closing force

DIG. 4

FIRE RESISTANCE

0

not approved for use on fire/ smoke resisting door assemblies

1

suitable for use on fire/smoke resisting door assemblies, subject to satisfactory assessment of the contribution of the lock or latch to the fire resistance of specified fire/smoke resisting door assemblies. Such assessment is beyond the scope of this European Standard

DIG. 5

SAFETY

0

no safety requirements

DIG. 6

CORROSION AND TEMPERATURE RESISTANCE

0

no defined corrosion resistance, no temperature requirement

A

low corrosion resistance, no temperature requirement

B

moderate corrosion resistance, no temperature requirement

C

high corrosion resistance, no temperature requirement

D

very high corrosion resistance, no temperature requirement

E

moderate corrosion resistance, temperature requirement: from –20 °C to +80 °C

F

high corrosion resistance, temperature requirement: from –20 °C to +80 °C

G

very high corrosion resistance, temperature requirement: from –20 °C to +80 °C

DIG. 7

SECURITY AND DRILL RESISTENCE

1

minimum security and no drill resistance

2

Low security and no drill resistance

3

medium security and no drill resistance

4

high security and no drill resistance

5

high security with drill resistance

6

very high security and no drill resistance

7

very high security with drill resistance

DIG. 8

FIELS OF DOOR APPLICATION

A

mortice lock, unrestricted application

B

mortice lock, highed door

C

mortice lock, sliding door

D

rim lock, unrestricted application

E

rim lock, hinged door

F

rim lock, sliding door

H

mortice lock, hinged door, supported

J

rim lock, hinged door, inwards

K

mortice lock, hinged door, locked from inside

L

mortice lock, sliding door, locked from inside

M

rim lock, hinged door, locked from inside

N

rim lock, sliding door, locked from inside

P

mortice lock, hinged door, supported, locked from inside

R

rim lock, hinged door, inwards, locked from inside

S

mortice lock, unrestricted application, locked from inside

T

rim lock, unrestricted application, locked from inside

DIG. 9

TYPE OF KEY OPERATION AND LOCKING

D

lever lock or latch, manually locking

E

lever lock or latch, automatically locking

F

lever lock or latch, manually locking with intermediate locking

G

lock or latch without key operation, manually locking

H

lock without key operation, automatically locking

0

not apllicable

A

cylinder lock or latch, manually locking

B

cylinder lock or latch, automatically locking

C

cylinder lock or latch, mmanually locking with intermediate locking

DIG. 10

TYPE OF SPINDLE OPERATION

0

lock or latch witout follower

1

lock or latch for knob or sprung lever handle operation

2

lock or latch for unsprung lever handle operation

3

lock or latch for heavy duty unsprung lever handle operation

4

lock or latch for heavy duty unsprung lever handle operation specified by the manufacturer

DIG. 11

KEY IDENTIFICATION

0

no requitements

A

minimum three detaining elements

B

minimum five detaining elements

C

minimum five detaining elements,extended number of effective differs

D

minimum six detaining elements

E

minimum six detaining elements,extended number of effective differs

F

minimum seven detaining elements

G

minimum seven detaining elements,extended number of effective differs

H

minimum eight detaining elements,extended number of effective differs

NORMA

EN1125

DIG. 1

CATEGORY OS USE

3

high frequency of use by public and others with little incentive to exercise care, i.e. where is a chance of accident occurring and of misure

DIG. 2

DURABILITY

6

100 000 test cycles

7

200 000 test cycles

DIG. 3

DOOR MASS

5

up to 100 kg door measure

6

up to 200kg door measure

7

above 200kg door measure

DIG. 4

FIRE RESISTANCE

0

not approved for use on fire/ smoke door assemblies

A

suitable for use on smoke door assemblies, subject to satisfactory assessment of the contribution of the panic/ emergency device to the smoke resistance of specified smoke door assemblies

B

suitable for use on fire/smoke door assemblies, subject to satisfactory assessment of the contribution of the panic/ emergency device to the fire resistance of specified fire/smoke door assemblies.

DIG. 5

SAFETY

1

All panic devices have a critical safety function therefore only the top grade - 1 – is identified

DIG. 6

CORROSION

3

high resistance (96 salt spray hours)

4

very high resistance (240 salt spray hours)

DIG. 7

SECURITY

2

1 000 N

DIG. 8

PROJECTION OF THE DEVICE

1

projeção até 150mm (projeção grande)

2

projeção até 100mm (projeção normal)

DIG. 9

TYPE OF DEVICE

A

panic device with push bar operation

B

panic device with touch bar operation

DIG. 10

FIELS OF DOOR APPLICATION

A

outward opening - Single & double exit doors; active & inactive leaf

B

outward opening - Single exit door only

C

outward opening – double exit door; inactive door

NORMA

EN179

DIG. 1

CATEGORY OS USE

3

for use by people with a high incentive to exercise care and with a small chance of misuse - keys shall resist a torque of 2,5Nm and still be sable

DIG. 2

DURABILITY

6

100.000 cycles

7

200.000 cycles

DIG. 3

DOOR MASS AND CLOSING FORCE

5

up to 100 kg

6

up to 200 kg

7

over 200 kg

DIG. 4

FIRE RESISTANCE

0

not approved for use on fire resistant / smoke control door assemblies

A

suitable for use on smoke control door assemblies

B

suitable for use on fire resistant smoke control door

DIG. 5

SAFETY

1

all panic closure devices have a very important personnel safety function, therefore only the highest degree - 1 - is identified

DIG. 6

CORROSION AND TEMPERATURE RESISTANCE

A

high corrosion resistance (96h), no temperature requirement

B

no corrosion resistence requirement: resistence -25/65ºC temperature extremes

DIG. 7

KEY RELATED SECURITY

2

300 Min. number of effective differs / 3 Min. number of movable detainers.

3

15 000 Min. number of effective differs / 5 Min. number of movable detainers.

4

30 000 Min. number of effective differs / 5 Min. number of movable detainers.

5

30 000 Min. number of effective differs / 6 Min. number of movable detainers.

DIG. 8

Projeção do equipamento

1

projeção até 150mm (projeção grande)

2

projeção até 100mm (projeção normal)

A

dispositivo de fecho de emergência com acionamento por “muleta de puxador

B

dispositivo de fecho de emergência com acionamento por “placa de empurrar

DIG. 9

Tipo de acionamento do equipamento

A

dispositivo de fecho antipânico acionado por “barra de alavanca

B

dispositivo de fecho antipânico acionado por “barra de pressão

DIG. 10

Campo de aplicação

A

abertura para o exterior - Porta de 1 folha, porta de 2 folhas; folha ativa ou inativa

B

abertura para o exterior - Apenas porta de 1 folha

C

abertura para o exterior - Porta de 2 folhas, apenas a folha inativa

Norma

EN1303

DIG. 1

CATEGORY OS USE

1

for use by people with a high incentive to exercise care and with a small chance of misuse - keys shall resist a torque of 2,5Nm and still be sable

DIG. 2

DURABILITY

4

25.000 cycles

5

50.000 cycles

6

100.000 cycles

DIG. 3

DOOR MASS AND CLOSING FORCE

DIG. 4

FIRE RESISTANCE

0

not approved for use on fire resistant / smoke control door assemblies

A

suitable for use on smoke control door assemblies

B

suitable for use on fire resistant smoke control door

DIG. 5

SAFETY

sem requisito

DIG. 6

CORROSION AND TEMPERATURE RESISTANCE

0

no corrosion or temperature resistence requirements

A

high corrosion resistance (96h), no temperature requirement

B

no corrosion resistence requirement: resistence -25/65ºC temperature extremes

C

high corrosion resistance (96h), -25/65ºC temperature extremes

DIG. 7

KEY RELATED SECURITY

1

100 Min. number of effective differs / 2 Min. number of movable detainers

2

300 Min. number of effective differs / 3 Min. number of movable detainers.

3

15 000 Min. number of effective differs / 5 Min. number of movable detainers.

4

30 000 Min. number of effective differs / 5 Min. number of movable detainers.

5

30 000 Min. number of effective differs / 6 Min. number of movable detainers.

6

100 000 Min. number of effective differs / 6 Min. number of movable detainers.

DIG. 8

ATTACK RESISTENCE

0

no resistance against drilling; no resistance against mechanical attack.

A

3/5 min resistance against drilling; resistance against mechanical attack except plug/cylinder extraction.

B

5/10 min resistance against drilling; resistance against mechanical attack except plug/cylinder extraction

C

3/5 min resistance against drilling; resistance against mechanical attack.

D

5/10 min resistance against drilling; resistance against mechanical attack.